회사소개 | Home | Sitemap | E-mail  
 
   
 
  Home > 발전기 > 상용 발전기
 
 
 
 
 
 
 
상용 디젤 발전기(50Hz) | 상용 디젤 발전기(60Hz) | 가스엔진 발전기(50Hz) | 가스엔진 발전기(60Hz)
  ※ 원하시는 기종명을 클릭해 주세요.
   
발전기 출력 기관소요출력 계통연계의 경우 계통분리의 경우
kVA kW kW 750min-1 1000min-1 1500min-1 750min-1 1000min-1 1500min-1
75 60 66.7     6HAL2C
(92/125)※
     
100 80 89.0         6HAL2C
(115/156)※
125 100 110.4     6HAL2C-T
(120/163)※
   
132.5 106 116.9         6HAL2C-T
(150/204)※
165 132 145.1     6HAL2C-HT
(162/220)※
   
180 144 158.2         6HAL2C-HT
(202/275)
187.5 150 164.8     6HAL2C-DT
(196/266)※
   
217.5 174 191.2        
225 180 197.6          
250 200 219.8   6NY16L-SN
(279/380)
    6NY16L-SN
(279/380)
6HAL2C-DT
(245/333)
275 220 241.5      
312.5 250 273.2        
379 360 393.4     EP350      
487.5 390 426.2     12LAALC-DT
(447/608)
     
510 408 443.0   6N18AL-EN
(552/750)
     
562.5 450 488.6   *12LALC-ST
(490/666)
     
625 500 537.6         12LAALC-DT
(559/759)
650 520 555.0          
700 560 597.7   6N21AL-EN
(780/1060)
    6N18AL-EN
(660/897)
*12LALC-ST
(609/827)
750 600 643.8        
850 680 729.6          
900 720 771.7          
1000 800 857.4   8N21AL-EN
(1040/1414)
    6N21AL-EN
(970/1319)
 
1125 900 964.6        
1200 960 1028.9       8N21AL-EN
(1300/1768)
 
1500 1200 1286.2          
2375 1900 2027.7 6N330L-EN
(2140/2910)
         
2500 2000 2134.5     6N330L-EN
(2354/3200)
   
2750 2200 2347.9 8N330L-EN
(2670/3630)
       
3125 2500 2668.1     8N330L-EN
(3089/4200)
   
3625 2900 3055.8          
1. 사용 목적에 따라서는 본 기종 선정과 다소 다를 수 있습니다. 기종 선정에 대해서는 당사와 상담해 주세요.
2. 표의 기종은 연료유를 A중유로서 선정했습니다. 저등급유 및 등유가 사용되고 있는 경우는 상담해 주세요.
3. 일계통 냉각방식, 기관구동 라디에이터의 경우는 본 표의 기종 선정과 약간 다를 수 있으므로 상담해 주세요.
*표는 라디에이터 냉각 사양만
4. 표 이외의 용량이 필요한 때에는 상담해 주세요.
5. ※표시된 기종은 대기오염 방지법상 "매연발생시설" 적용외기종(연료 소비량이 중유 환산50L/h미만)입니다.
6. 피크 컷의 경우에서도, 계통연계·분리에 의해 출력이 다릅니다.
7. 기관 소요출력은 참고가격이며, 발전기 효율에 의해서 바뀝니다.
 
상용 디젤 발전기(50Hz) | 상용 디젤 발전기(60Hz) | 가스엔진 발전기(50Hz) | 가스엔진 발전기(60Hz)
  ※ 원하시는 기종명을 클릭해 주세요.
   
발전기 출력 기관소요출력 계통연계의 경우 계통분리의 경우
kVA kW kW 720min-1 900/1200min-1 1800min-1 720min-1 900/1200min-1 1800min-1
90 72 79.4     6HAL2C
(102/139)※
    6HAL2C
(128/174)※
110 88 97.0        
125 100 109.5     6HAL2C-T
(162/220)※
   
140 112 122.7        
180 144 157.5         6HAL2C-T
(202/275)
217.5 174 190.4     6HAL2C-HT
(196/266)
   
225 180 196.9     6HAL2C-DT
(222/302)
   
248.75 199 217.7         6HAL2C-HT
(245/333)
275 220 240.7          
287.5 230 252.2           6HAL2C-DT
(278/378)
312.5 250 273.2          
375 300 327.9   6NY16L-UN
(353/480)
    6NY16L-UN
(353/480)
 
387.5 310 338.8        
400 320 350.5        
379 360 374.2     EP350      
500 400 435.7   6N18AL-EN
(552/750)
       
567.5 454 494.6   12LAALC-DT
(522/710)
     
600 480 521.7        
625 500 537.6   *12LALC-ST
(554/753)
     
636.25 509 551.5          
700 560 597.0   6N21AL-EN
(780/1060)
    6N18AL-EN
(660/897)
12LAALC-DT
(648/880)
750 600 639.7      
800 640 682.3         *12LALC-ST
(693/942)
900 720 771.7          
1000 800 852.9   8N21AL-EN
(1040/1414)
    6N21AL-EN
(970/1319)
 
1125 900 959.5        
1200 960 1032.3       8N21AL-EN
(1300/1768)
 
1500 1200 1275.2          
2375 1900 2027.7 6N330L-EN
(2140/2910)
         
2500 2000 2134.5     6N330L-EN
(2354/3200)
   
2750 2200 2347.9 8N330L-EN
(2670/3630)
       
3125 2500 2668.1     8N330L-EN
(3089/4200)
   
3625 2900 3085.1          
1. 사용 목적에 따라서는 본기종 선정과 다소 다를 수 있습니다. 기종 선정에 대해서는 당사와 상담해 주세요.
2. 표의 기종은 연료유를 A중유로서 선정했습니다. 저등급유 및 등유가 사용되고 있는 경우는 상담해 주세요.
3. 일계통 냉각방식, 기관구동 라디에이터의 경우는 본 표의 기종 선정과 약간 다를 수 있으므로 상담해 주세요.
*표는 라디에이터 냉각 사양만
4. 표 이외의 용량이 필요한 때에는 상담해 주세요.
5. ※표시된 기종은 대기오염 방지법상 "매연발생시설" 적용외기종(연료 소비량이 중유 환산50L/h미만)입니다.
6. 피크 컷의 경우에서도, 계통연계·분리에 의해 출력이 다릅니다.
7. 기관 소요 출력은 참고가격이며, 발전기 효율에 의해서 바뀝니다.
 
상용 디젤 발전기(50Hz) | 상용 디젤 발전기(60Hz) | 가스엔진 발전기(50Hz) | 가스엔진 발전기(60Hz)
  ※ 원하시는 기종명을 클릭해 주세요.
   
발전기
출력
기관소요출력 계통연계의 경우 계통분리의 경우
kVA kW kW 1000min-1 1500min-1 1000min-1 1500min-1
389 370 -   EP370G    
1. 사용 목적에 따라서는 본기종 선정과 다소 다를 수 있습니다. 기종 선정에 대해서는 당사와 상담해 주세요.
2. 표의 기종은 연료가스 13A로서 선정되어 있습니다.
3. 냉각방식, 기관구동라디에이터에 따라서는 본 표의 기종선정과 약간 다를 수 있으므로 상담해 주세요.
*표는 라디에이터 냉각 사양만
4. 표 이외의 용량이 필요한 때에는 상담해 주세요.
5. 기관소요출력은 참고가격이며 발전기효율에 따라 바뀝니다.
 
상용 디젤 발전기(50Hz) | 상용 디젤 발전기(60Hz) | 가스엔진 발전기(50Hz) | 가스엔진 발전기(60Hz)
  ※ 원하시는 기종명을 클릭해 주세요.
   
발전기
출력
기관소요
출력
계통연계의 경우 계통분리의 경우
kVA kW kW 1200min-1 1800min-1 1200min-1 1800min-1
421.05 400 -   EP400G    
1. 사용 목적에 따라서는 본기종 선정과 다소 다를 수 있습니다. 기종 선정에 대해서는 당사와 상담해 주세요.
2. 표의 기종은 연료가스 13A로서 선정되어 있습니다.
3. 냉각방식, 기관구동라디에이터에 따라서는 본 표의 기종선정과 약간 다를 수 있으므로 상담해 주세요.
*표는 라디에이터 냉각 사양만
4. 표 이외의 용량이 필요한 때에는 상담해 주세요.
5. 기관소요출력은 참고가격이며 발전기효율에 따라 바뀝니다.